Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
Home Print this page Email this page
Users Online:167
ORIGINAL ARTICLE
Year : 2021  |  Volume : 9  |  Issue : 1  |  Page : 35-39

Delayed perforation of the right ventricle by pacemaker/automated implantable cardioverter-defibrillator lead: A single-center experience


Department of Cardiovascular and Thoracic Surgery, King George's Medical University, Lucknow, Uttar Pradesh, India

Correspondence Address:
Sushil K Singh
Department of Cardiovascular and Thoracic Surgery, King George's Medical University, Lucknow - 226 003, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/heartindia.heartindia_43_20

Rights and Permissions

Introduction: Cardiac perforation by pacemaker/automatic implantable cardioverter-defibrillator (AICD) lead can be a life-threatening emergency. Delayed cardiac perforation by pacemaker/AICD lead is defined as perforation occurring after a period of 1 month following pacemaker/AICD insertion. Delayed perforation is often difficult to identify at first and needs active intervention to prevent complications and death. Materials and Methods: Patients presenting with and operated upon for delayed cardiac perforation following pacemaker/AICD insertion were included in this study. The study was conducted between April 2019 and April 2020. Results: Three patients reported with delayed cardiac perforation after pacemaker insertion. All patients had syncopal episodes, and detection could be easily done using chest X-ray and trans-thoracic echocardiography (TTE). Two patients had active fixation leads used for anchoring the lead in the right ventricle (RV). Two patients were female, while one was a male, and all had perforation through the RV apex. Lead reposition was done in two cases, thereby preventing the need for placing additional leads, while a new lead was required in the third case. Conclusion: Early identification of cardiac perforation can be done easily with chest X-ray and TTE, but a high index of suspicion should be kept in mind. Surgical or fluoroscopic intervention may be planned depending on the available expertise and patient condition.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed82    
    Printed0    
    Emailed0    
    PDF Downloaded14    
    Comments [Add]    

Recommend this journal