Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
Home Print this page Email this page
Users Online:48
ORIGINAL ARTICLE
Year : 2020  |  Volume : 8  |  Issue : 2  |  Page : 80-84

Safety and efficacy of transcatheter device closure of patent ductus arteriosus in pediatric patients: Long-term outcomes


Department of Cardiology, U. N. Mehta Institute of Cardiology and Research Centre, B. J. Medical College, Ahmedabad, Gujarat, India

Correspondence Address:
Dr. Jayal Hasmukhbhai Shah
Bungalow No. 3, Riviera 30 Society, Near Prahladnagar Auda Garden, Satellite, Ahmedabad - 380 015, Gujarat
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/heartindia.heartindia_6_20

Rights and Permissions

Aims: Patent ductus arteriosus (PDA) is among the most prevalent congenital heart diseases in current times. The aim of this study is to evaluate contemporarily the safety and efficacy of transcatheter device closure of PDA at long-term follow-up. Materials and Methods: Transcatheter closure of PDA was attempted in 205 children between 2008 and 2015 using the Amplatzer duct occlude (ADO). Ductal anatomy was accurately delineated on lateral and right anterior oblique view on aortic angiogram. All children underwent complete clinical evaluation, electrocardiography, chest X-rays, and echocardiography prior to discharge and at 1-month, 6-month, and annual follow-up thereafter. Results: Of a total of 205 cases, 64% were females; the mean age was 7.92 ± 3.61 years (1–17 years), while the mean weight was 16.68 ± 10.82 (5–41 kg). ADOs-I were used in all the cases. The procedure was successful in 99.03% of patients with excellent results. Two patients required surgical closure due to device-induced aortic obstruction and left pulmonary stenosis. There were no cases of procedural deaths, device embolization, device infection, and infective endocarditis. All children fared well at a median follow-up of 94 months with no complications. Conclusion: The long-term data showed that percutaneous transcatheter closure of PDA using ADO was safe and effective in pediatric population with minimal complications.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed123    
    Printed8    
    Emailed0    
    PDF Downloaded35    
    Comments [Add]    

Recommend this journal